Command Line Interface
4-18
4
Command Usage
Communication protocols provided by devices such as terminals and modems
often require a specific parity bit setting.
Example
To specify no parity, enter this command:
speed
This command sets the terminal line’s baud rate. This command sets both the
transmit (to terminal) and receive (from terminal) speeds. Use the no form to restore
the default setting.
Syntax
speed bps
no speed
bps - Baud rate in bits per second.
(Options: 9600, 19200, 38400, 57600, 115200 bps, or auto)
Default Setting
auto
Command Mode
Line Configuration
Command Usage
Set the speed to match the baud rate of the device connected to the serial
port. Some baud rates available on devices connected to the port might not be
supported. The system indicates if the speed you selected is not supported. If
you select the “auto” option, the switch will automatically detect the baud rate
configured on the attached terminal, and adjust the speed accordingly.
Example
To specify 57600 bps, enter this command:
stopbits
This command sets the number of the stop bits transmitted per byte. Use the no
form to restore the default setting.
Syntax
stopbits {1 | 2}
1 - One stop bit
2 - Two stop bits
Console(config-line)#parity none
Console(config-line)#
Console(config-line)#speed 57600
Console(config-line)#